Choose the S7-1200 (including the newer S7-1200 G2) for compact machines with modest I/O, and the S7-1500 when you need more performance, memory, communication and scalability. Both are programmed in TIA Portal, so the skills transfer, and Siemens now offers fail-safe versions of both. The decision usually comes down to machine size, motion requirements, network design and budget rather than any single headline specification.
What is the difference between the S7-1200 and the S7-1500?
The S7-1200 is Siemens' compact basic controller, and the S7-1500 is its modular advanced controller. Siemens describes the S7-1500 as a high-performance controller for complex machines and processes that is modular, scalable and rated IP20 for control cabinets, with PROFINET built into the CPUs and OPC UA listed among its communication options. Every S7-1500 CPU supports motion control, and technology CPUs add functions such as extended gear synchronisation, cyclic cams and kinematics. Siemens markets the S7-1200 G2 as a compact PLC for basic automation, and its own presentation shows the S7-1200 G2 sitting below the S7-1500 as application complexity rises.
There are now two S7-1200 generations. Siemens introduced the S7-1200 G2 in 2024 as the first new controller generation in ten years, with integrated motion control, flexible machine safety, more memory and NFC access to diagnostic data, and it is engineered from TIA Portal V20.
How do the specifications compare?
The specifications below come from Siemens datasheets and Siemens' G2 launch slides for specific CPUs, so use them as examples rather than family limits.
| S7-1200 CPU 1214C DC/DC/DC | S7-1200 G2 CPU 1214(F)C | S7-1500 CPU 1511-1 PN | |
|---|---|---|---|
| Bit operation time | 0.085 µs typical | 37 ns | 60 ns typical |
| Program / data memory | 100 KB work memory | 250/300 kB program RAM, 750 kB data RAM | 150 KB program, 1 MB data |
| Integrated I/O | 14 digital in, 10 digital out | 14 digital in, 10 digital out | None listed; I/O is added with modules |
| PROFINET | 16 IO devices as controller | Up to 31 PROFINET devices, IRT | One interface with two ports |
| Motion | 4 axes via pulse/direction outputs | 4 typical, 10 maximum positioning axes | 800 motion resources; 5 positioning axes at 4 ms, 10 at 8 ms (typical) |
| Display on CPU | Not listed | Not listed | 3.45 cm display with 8 keys |
Two points stand out. First, the entry S7-1500 CPU is not faster than the S7-1200 G2 on bit operations, so a faster instruction time alone is not a reason to pick the S7-1500. Second, the S7-1500 range is far wider than the one CPU in this table: Siemens describes several CPU versions, each in multiple performance classes, so larger S7-1500 CPUs offer far more memory and speed than the 1511-1 PN.
When is the S7-1200 the right choice?
The S7-1200 family suits standalone machines, small production cells and building services where the I/O count is modest and cost matters. The CPUs have integrated I/O, which saves cabinet space and cost on a small machine, and they are the usual choice for OEM machine builders making repeatable equipment. If you want the newer features, the S7-1200 G2 adds more memory, up to 31 PROFINET devices, integrated motion control and fail-safe options, and Siemens says the G2 takes fail-safe I/O and engineering into STEP 7 Basic without a separate safety licence from V20.
When is the S7-1500 the right choice?
The S7-1500 suits larger lines, process plants, complex motion and anything where you need headroom or diagnostics. Typical reasons to step up are more I/O spread across several PROFINET segments, technology CPUs for demanding motion (gear synchronisation, cams and kinematics), larger programs and data, a front display for diagnostics without a laptop, and integration into plant-wide systems through standardised communication. Fail-safe CPUs exist in the S7-1500 family too: Siemens' application documentation describes a fail-safe S7-1500 controller used for emergency-stop functions up to SIL 3 and PL e, with the caveat that the whole safety function, including monitored contactors, must be designed to reach that level.
What about the software and licensing?
Both families are programmed in TIA Portal, but your licence edition limits which controllers you can program. Siemens describes STEP 7 Professional as able to configure, program, test and diagnose all generations of SIMATIC controllers, and STEP 7 Basic as a price-optimised subset of it. Check the licence matrix for your TIA Portal version before you buy, because it decides whether Basic covers the CPU you need. Version support also matters: the S7-1200 G2 arrived with V20, as covered in our TIA Portal version guide.
What do typical projects look like in practice?
These are illustrative scenarios, not Siemens recommendations, and your own I/O count and requirements should decide.
| Scenario | Likely starting point | Reasoning |
|---|---|---|
| Stand-alone packaging machine with a few dozen I/O points and a couple of servo axes | S7-1200 or S7-1200 G2 | Integrated I/O and basic motion fit the machine, and the G2 adds memory and 31 PROFINET devices |
| Water pumping station with modest I/O and remote monitoring | S7-1200 family | Compact, low cost, and enough for a handful of drives and instruments |
| Multi-station line with many drives, several PROFINET segments and plant-wide data | S7-1500 | More performance classes, memory and communication headroom |
| Machine needing gear synchronisation, cams or kinematics | S7-1500 technology CPU | Siemens lists these functions for technology CPUs |
| Machine with machine-level safety functions and motion in one controller | S7-1200 G2 F-CPU or S7-1500 F-CPU | Both families have fail-safe options; choose by the rest of the requirements |
A frequent mistake is to pick on price alone and then run out of memory, communication ports or motion resources late in the project. Migrating logic between families is possible in TIA Portal, but it is still a job to plan, test and document.
How should you decide, and what about learning?
Work through five questions, and let the answers pick the CPU:
- How many I/O points and PROFINET devices now, and how many in five years?
- Is there coordinated motion, and how many axes at what cycle time?
- Do you need fail-safe functions, and are they machine-level or plant-level?
- How much program and data memory will the application need, including recipes and logging?
- Who will maintain it, and what does their site already standardise on?
For learners, the choice matters less than it seems. The programming workflow in TIA Portal (tags, blocks, ladder, PROFINET configuration, simulation) is the same for both families, and the differences show up in the hardware catalogue, memory limits and technology objects. Start with our beginner's guide to TIA Portal, and if you are comparing platforms, read Siemens vs Allen-Bradley.
How EDWartens can help
The EDWartens UK Professional Module teaches the TIA Portal workflow in a five-day live online class (certificate states V19) using simulation, so you practise on a virtual S7 PLC rather than a physical S7-1200 or S7-1500 rig. It includes self-paced Basic Engineering modules and career support. It costs £2,140 + VAT (£2,568), with a £100 deposit option and a maximum of 10 learners per cohort. The course is Siemens-focused, and the CPD certificate is not a regulated qualification. The free Siemens TIA Portal course is a good place to start, or sign up.