Physical AIUpdated 21 October 20268 min read

Siemens S7-1500 vs S7-1200: Which PLC Should You Choose?

Choose the S7-1200 (or the newer S7-1200 G2) for compact machines with modest I/O, and the S7-1500 for larger, faster, more demanding systems. Siemens positions them as its basic and advanced controllers, and both are programmed in TIA Portal. Raw bit speed is not the deciding factor: the G2 lists 37 ns, the entry S7-1500 60 ns.

SiemensS7-1500S7-1200S7-1200 G2PLC SelectionTIA Portal
Woman engineer working on a laptop at a mechatronics test rig with wiring harnesses and sensors

Key takeaways

  • Siemens positions the S7-1200 as its basic controller and the S7-1500 as the advanced one, and both are programmed in TIA Portal.
  • The S7-1200 G2 lists 37 ns bit performance, faster than the 60 ns of the entry S7-1500 CPU 1511-1 PN, so bit speed alone does not decide the choice.
  • The S7-1200 G2 supports up to 31 PROFINET devices, against 16 IO devices for the S7-1200 CPU 1214C in its datasheet.
  • The S7-1500 CPU 1511-1 PN offers 150 KB program and 1 MB data memory, a 3.45 cm display and 800 motion control resources.
  • Fail-safe versions exist for both families, and the S7-1200 G2 needs no separate safety licence from TIA Portal V20.

Choose the S7-1200 (including the newer S7-1200 G2) for compact machines with modest I/O, and the S7-1500 when you need more performance, memory, communication and scalability. Both are programmed in TIA Portal, so the skills transfer, and Siemens now offers fail-safe versions of both. The decision usually comes down to machine size, motion requirements, network design and budget rather than any single headline specification.

What is the difference between the S7-1200 and the S7-1500?

The S7-1200 is Siemens' compact basic controller, and the S7-1500 is its modular advanced controller. Siemens describes the S7-1500 as a high-performance controller for complex machines and processes that is modular, scalable and rated IP20 for control cabinets, with PROFINET built into the CPUs and OPC UA listed among its communication options. Every S7-1500 CPU supports motion control, and technology CPUs add functions such as extended gear synchronisation, cyclic cams and kinematics. Siemens markets the S7-1200 G2 as a compact PLC for basic automation, and its own presentation shows the S7-1200 G2 sitting below the S7-1500 as application complexity rises.

There are now two S7-1200 generations. Siemens introduced the S7-1200 G2 in 2024 as the first new controller generation in ten years, with integrated motion control, flexible machine safety, more memory and NFC access to diagnostic data, and it is engineered from TIA Portal V20.

Siemens SIMATIC S7-1500 modular controller with CPU and I/O modules on a mounting rail
Siemens SIMATIC S7-1500 modular controller with CPU and I/O modules on a mounting railPhoto: Palatinatian, CC BY 3.0, via Wikimedia Commons

How do the specifications compare?

The specifications below come from Siemens datasheets and Siemens' G2 launch slides for specific CPUs, so use them as examples rather than family limits.

S7-1200 CPU 1214C DC/DC/DCS7-1200 G2 CPU 1214(F)CS7-1500 CPU 1511-1 PN
Bit operation time0.085 µs typical37 ns60 ns typical
Program / data memory100 KB work memory250/300 kB program RAM, 750 kB data RAM150 KB program, 1 MB data
Integrated I/O14 digital in, 10 digital out14 digital in, 10 digital outNone listed; I/O is added with modules
PROFINET16 IO devices as controllerUp to 31 PROFINET devices, IRTOne interface with two ports
Motion4 axes via pulse/direction outputs4 typical, 10 maximum positioning axes800 motion resources; 5 positioning axes at 4 ms, 10 at 8 ms (typical)
Display on CPUNot listedNot listed3.45 cm display with 8 keys

Two points stand out. First, the entry S7-1500 CPU is not faster than the S7-1200 G2 on bit operations, so a faster instruction time alone is not a reason to pick the S7-1500. Second, the S7-1500 range is far wider than the one CPU in this table: Siemens describes several CPU versions, each in multiple performance classes, so larger S7-1500 CPUs offer far more memory and speed than the 1511-1 PN.

When is the S7-1200 the right choice?

The S7-1200 family suits standalone machines, small production cells and building services where the I/O count is modest and cost matters. The CPUs have integrated I/O, which saves cabinet space and cost on a small machine, and they are the usual choice for OEM machine builders making repeatable equipment. If you want the newer features, the S7-1200 G2 adds more memory, up to 31 PROFINET devices, integrated motion control and fail-safe options, and Siemens says the G2 takes fail-safe I/O and engineering into STEP 7 Basic without a separate safety licence from V20.

When is the S7-1500 the right choice?

The S7-1500 suits larger lines, process plants, complex motion and anything where you need headroom or diagnostics. Typical reasons to step up are more I/O spread across several PROFINET segments, technology CPUs for demanding motion (gear synchronisation, cams and kinematics), larger programs and data, a front display for diagnostics without a laptop, and integration into plant-wide systems through standardised communication. Fail-safe CPUs exist in the S7-1500 family too: Siemens' application documentation describes a fail-safe S7-1500 controller used for emergency-stop functions up to SIL 3 and PL e, with the caveat that the whole safety function, including monitored contactors, must be designed to reach that level.

What about the software and licensing?

Both families are programmed in TIA Portal, but your licence edition limits which controllers you can program. Siemens describes STEP 7 Professional as able to configure, program, test and diagnose all generations of SIMATIC controllers, and STEP 7 Basic as a price-optimised subset of it. Check the licence matrix for your TIA Portal version before you buy, because it decides whether Basic covers the CPU you need. Version support also matters: the S7-1200 G2 arrived with V20, as covered in our TIA Portal version guide.

Introducing Siemens PLCs in 5 Minutes: S7‑1200, S7‑1500 & ET200SP
Choosing the Right S7-1200 PLC: A Step-by-Step Guide for Industrial Applications

What do typical projects look like in practice?

These are illustrative scenarios, not Siemens recommendations, and your own I/O count and requirements should decide.

ScenarioLikely starting pointReasoning
Stand-alone packaging machine with a few dozen I/O points and a couple of servo axesS7-1200 or S7-1200 G2Integrated I/O and basic motion fit the machine, and the G2 adds memory and 31 PROFINET devices
Water pumping station with modest I/O and remote monitoringS7-1200 familyCompact, low cost, and enough for a handful of drives and instruments
Multi-station line with many drives, several PROFINET segments and plant-wide dataS7-1500More performance classes, memory and communication headroom
Machine needing gear synchronisation, cams or kinematicsS7-1500 technology CPUSiemens lists these functions for technology CPUs
Machine with machine-level safety functions and motion in one controllerS7-1200 G2 F-CPU or S7-1500 F-CPUBoth families have fail-safe options; choose by the rest of the requirements

A frequent mistake is to pick on price alone and then run out of memory, communication ports or motion resources late in the project. Migrating logic between families is possible in TIA Portal, but it is still a job to plan, test and document.

How should you decide, and what about learning?

Work through five questions, and let the answers pick the CPU:

  1. How many I/O points and PROFINET devices now, and how many in five years?
  2. Is there coordinated motion, and how many axes at what cycle time?
  3. Do you need fail-safe functions, and are they machine-level or plant-level?
  4. How much program and data memory will the application need, including recipes and logging?
  5. Who will maintain it, and what does their site already standardise on?

For learners, the choice matters less than it seems. The programming workflow in TIA Portal (tags, blocks, ladder, PROFINET configuration, simulation) is the same for both families, and the differences show up in the hardware catalogue, memory limits and technology objects. Start with our beginner's guide to TIA Portal, and if you are comparing platforms, read Siemens vs Allen-Bradley.

How EDWartens can help

The EDWartens UK Professional Module teaches the TIA Portal workflow in a five-day live online class (certificate states V19) using simulation, so you practise on a virtual S7 PLC rather than a physical S7-1200 or S7-1500 rig. It includes self-paced Basic Engineering modules and career support. It costs £2,140 + VAT (£2,568), with a £100 deposit option and a maximum of 10 learners per cohort. The course is Siemens-focused, and the CPD certificate is not a regulated qualification. The free Siemens TIA Portal course is a good place to start, or sign up.

Start free

Learn PLC programming free, then practise the job

Free job simulation

PLC Programmer

Write the I/O list, program the line, run the FAT and handle a change request.

The first five days are free, no card needed.

Live UK jobs

PLC and automation jobs in the UK

Updated daily, with licensed visa sponsors marked.

Browse all engineering jobs

Frequently asked questions

Is the S7-1500 better than the S7-1200?

It is a different tier, not simply better. The S7-1500 is Siemens' advanced, modular controller with a wider range of CPU performance classes, technology CPUs and a front display. The S7-1200 is compact with integrated I/O, which is better value on small machines. Choose by I/O count, motion, memory and communication needs.

What is the S7-1200 G2?

The S7-1200 G2 is the second generation of Siemens' compact controller, announced in June 2024 as the first new generation in ten years. Siemens lists more memory, integrated motion control, flexible machine safety, up to 31 PROFINET devices and NFC access to diagnostics. It is engineered in TIA Portal V20 or later.

Can you program both the S7-1200 and S7-1500 in TIA Portal?

Yes, both are engineered in TIA Portal, so ladder logic, tags, blocks and PROFINET skills transfer. The licence edition matters, though: Siemens describes STEP 7 Professional as covering all generations of SIMATIC controllers and STEP 7 Basic as a price-optimised subset, so check the licence matrix before buying.

Which PLC should a beginner learn first?

Most beginners start with the S7-1200 because it is compact and widely used in training. The programming workflow is the same on the S7-1500, so little is lost by starting on either. You can also practise in the S7-PLCSIM simulator without hardware, and free browser simulators let you rehearse ladder logic.

Do the S7-1200 and S7-1500 support safety functions?

Both families have fail-safe variants. Siemens' G2 material lists fail-safe F-CPUs, F-I/O and PROFIsafe for the S7-1200 G2, with no separate safety licence from TIA Portal V20. Siemens' application documentation describes fail-safe S7-1500 CPUs reaching SIL 3 and PL e, provided the complete safety function is designed correctly.

Sources

  1. Siemens: SIMATIC S7-1500 product page
  2. Siemens press release: New generation of SIMATIC S7-1200 G2 controllers (6 June 2024)
  3. Siemens SIMATIC S7-1200 G2 launch webinar technical slides
  4. Siemens datasheet (distributor copy): SIPLUS S7-1200 CPU 1214C DC/DC/DC, 6AG1214-1AG40-5XB0
  5. Siemens datasheet (distributor copy): SIMATIC S7-1500 CPU 1511-1 PN, 6AG1511-1AK02-7AB0
  6. Siemens: SIMATIC STEP 7 (TIA Portal) Basic and Professional
  7. Siemens application example: Emergency Stop up to PL e / SIL 3 with a fail-safe S7-1500 controller

Share this article

About the author

EDWartens Team

EDWartens Instructional Team

The EDWartens instructional team brings together UK-based automation engineers, certified Siemens and Rockwell specialists, and industry practitioners with decades of combined experience in PLC programming, SCADA engineering, and industrial AI.

View all articles by EDWartens

Ready to become job-ready?

Start with a free course today, or train live in Siemens PLC, HMI and SCADA on the Professional Module.

Related articles

Physical AI

Siemens TIA Portal Course UK: Options, Versions, Prices

UK options for a Siemens TIA Portal course range from Siemens SITRAIN classroom and online courses, a 3-day Make UK course at £995 + VAT and evening college courses (free if eligible), to online programmes and free courses. SITRAIN prices five-day courses by personalised quotation; the right choice depends on version, format and budget.

Read article
Physical AI

Siemens TIA Portal for Beginners: Your First PLC Project

TIA Portal is Siemens' single engineering environment for programming S7 PLCs, HMIs and drives. To start, install it, add an S7-1200 or S7-1500 CPU, write a start-stop rung in the Main [OB1] block and test it in a simulator. UK PLC Engineer adverts quoted a median of £60,000 in the six months to 21 October 2026 (ITJobsWatch).

Read article
Physical AI

TIA Portal V19 Features, and What V20 and V21 Changed

TIA Portal V19 (November 2023) centred on motion control, software units and Named Values. V20 followed in November 2024 and V21 was presented on 11 November 2025, so V21 is the newest release we could confirm. The EDWartens course certificate states V19, and the fundamentals carry across versions.

Read article
Physical AI

PROFINET Explained: How It Works and How to Design a Network

PROFINET is an open industrial Ethernet standard that runs real-time I/O and ordinary IT traffic on one cable. PI reports 89.2 million installed nodes at the end of 2025, and HMS Networks puts it at 30% of new industrial Ethernet nodes. This guide covers RT, IRT, TSN, topology, redundancy and fault-finding.

Read article