Free course · Building automation

Data Centre Cooling, BMS and DCIM

This free course explains how data centres are cooled, controlled and run: hot and cold aisles, CRAC and CRAH units, chilled water plant, economisers, liquid and immersion cooling for AI racks, cooling redundancy, BMS design, DCIM, and PUE, WUE and CUE. It suits UK mechanical, electrical and controls engineers and facilities staff, and helps with data centre engineer, BMS engineer and facilities roles on the UK sites that cluster around London and Slough.

Data Centre Cooling, BMS and DCIM is a free online intermediate Building automation course with 9 modules, about 7 hours of video lessons. Learning is free; an optional verifiable certificate costs £19 including VAT when you pass the final exam. Last updated 28 October 2026.

See the modules

Free to learn. Verifiable certificate £19 when you pass the final exam (optional, VAT included).

Level
Intermediate
Modules
9
Video
7 hours

Video time only: reading the notes, the quizzes and the final exam take extra time, at your own pace.

Price
Free

Outcome

What you will be able to do

Trace the heat path from chip to atmosphere and calculate the airflow and water flow a load needs; compare CRAC and CRAH units, air- and water-cooled plant, and containment options; explain economisers and chiller efficiency in COP and kW per ton; describe direct-to-chip, rear-door and immersion cooling for AI racks; size cooling units with redundancy and plan continuous cooling through a power failure; design BMS points, controllers and alarms that survive a single failure; use DCIM for capacity and change; and report PUE, WUE and CUE.

  • Trace the heat path and calculate the airflow and water flow a load needs
  • Compare CRAC and CRAH units, containment options and air- and water-cooled plant
  • Explain economisers and calculate chiller COP and kW per ton
  • Describe direct-to-chip, rear-door and immersion cooling for AI racks
  • Size cooling with N+1 and plan continuous cooling through a power failure
  • Design a BMS that survives a single controller failure, with points and alarms
  • Use DCIM to find the limiting resource and stranded capacity
  • Calculate PUE, WUE and CUE and explain what each misses

Software

None required. A spreadsheet for the calculations.

Hardware

None.

Syllabus

9 modules

Each module has video lessons, notes and a short quiz. The final exam closes the course.

  1. 1How a data centre is cooled2 lessonsLab
  2. 2CRAC, CRAH and chilled water3 lessonsLab
  3. 3Data centre HVAC in depth2 lessons
  4. 4Liquid and immersion cooling for AI2 lessons
  5. 5Designing the power and cooling infrastructure4 lessons
  6. 6BMS for data centres2 lessons
  7. 7DCIM, operations and management2 lessonsLab
  8. 8Sustainability, and what comes next3 lessonsLab
  9. 9Final Assessment1 lesson

How it works

How this course works

  1. Watch the video lessonsOne module at a time, at your own pace.
  2. Take the module quizA short quiz at the end of each module shows what stuck.
  3. Keep your notesWrite in My notes beside each module and ask the trainer if you are stuck.
  4. Practise in the labOptionalTry a task from the module in the EDWartens Lab, in your browser.
  5. Sit the final examPass it once you have been through the modules.
  6. Certificate, if you want oneOptionalPaid, and only after you pass. Anyone can check it online.

EDWartens Lab

Practise this in the EDWartens Lab

Lose a power feed, find a hot spot and read cooling and power loads against limits in the Lab's data-centre simulator.

Works alongside Data Centre Cooling, BMS and DCIM. The Lab is data-centre power and cooling practice in your browser: no install, no hardware, free to use. Sign in as a learner and it opens with your account.

Data-centre power and cooling: Run an AI data hall.

Levels to try with this course

Optional. Skip it whenever you like: it never blocks your progress or your certificate.

Why practise in a lab

Technical work is judged on what you can do: wiring, commissioning, finding a fault. Doing a task yourself teaches more than watching it a second time, and a lab lets you try it safely before you meet real equipment. It does not replace working on real hardware.

  • Practise safely, so a mistake costs nothing.
  • The lab checks your work like a site test, so you know when it is right.
  • Free, in your browser, with nothing to install.

Certificate

An optional certificate when you pass

Learning is free. Pass the final exam and you can have a certificate for £19, including VAT, with a number employers can check online. It records that you completed a free online course; it is not a regulated qualification or a CPD certificate.

  • Your name, the course, its study time and your final exam score
  • A unique certificate number and a QR code to its verification page
  • Issued by Wartens Ltd; add it to your LinkedIn profile in one click
  • Pay now or after you pass: it is issued the moment you pass the final

How the certificate works

Sample certificate for Data Centre Cooling, BMS and DCIM

Credits

Who made the lessons

The video lessons belong to their creators. EDWartens wrote the study plan, notes, quizzes and the final exam.

  • TEQNYAT

    the Datacenter Design & Operations Course episodes on power and cooling infrastructure, data centre management and operations, sustainability and green data centres, and emerging trends

  • MEP Academy

    the explainers on data centre cooling methods, hot and cold aisle containment, CRAC and CRAH units, chilled water systems, air- and water-cooled plant, data centre HVAC, refrigerant economisers, liquid cooling for AI and immersion cooling

  • Bryce Anderson

    the BMS design lessons for data centres: N+1 controller design, power and alarms

Jobs

Jobs this course can lead to

The skills in this course are used in BMS and building controls work, for example as a data centre engineer, a BMS engineer and a facilities engineer. No course can promise a job, and employers also look for experience, so read what live adverts ask for.

Questions

About this course

Last reviewed 28 October 2026.

Do I need data centre experience?
No, but it is an intermediate course, so basic mechanical or electrical knowledge helps. It traces the heat path step by step and works the calculations through. You need no software or hardware to follow it.
Does it cover liquid cooling for AI racks?
Yes. It compares direct-to-chip, rear-door and immersion cooling, and explains why AI racks change the cooling and the continuous cooling plan. It teaches how each works and where it fits, not a product recommendation.
Is this enough to get a job as a data centre engineer in the UK?
Not by itself. It gives you the cooling and BMS concepts, but UK operators and contractors also look for site experience, safe working records and vendor training. Use it to prepare for a junior role, then check current vacancies.
What does the Data Centre Cooling, BMS and DCIM course cover?
It has 9 modules. The first are “How a data centre is cooled”, “CRAC, CRAH and chilled water”, “Data centre HVAC in depth”, “Liquid and immersion cooling for AI” and “Designing the power and cooling infrastructure”, and 4 more follow. Each module has video lessons, notes and a short quiz.
Where does Data Centre Cooling, BMS and DCIM start and where does it end?
It starts with “How a data centre is cooled” and the last module is “Final Assessment”. The final exam closes the course, and passing it is what makes the optional £19 certificate available.
How long is Data Centre Cooling, BMS and DCIM?
9 modules with 21 lessons, about 7 hours of video lessons. The largest module is “Designing the power and cooling infrastructure” with 4 lessons. Video time only: reading the notes, the quizzes and the final exam take extra time, at your own pace.
Can I practise Data Centre Cooling, BMS and DCIM in the browser?
Yes. Some modules of Data Centre Cooling, BMS and DCIM have a practice level in the EDWartens Lab, marked Lab on the module list, so you can try the ideas in your browser without installing software.
Who is this course for?
HVAC, mechanical, controls and facilities engineers moving into data centres, and data centre technicians who want to understand the cooling and BMS behind their daily work. Basic HVAC knowledge is assumed.
How is it different from Data Centre Electrical and Critical Power?
That course covers the electrical side: power paths, UPS, generators and electrical studies. This one covers cooling, BMS, DCIM and sustainability. Together they cover the two halves of data centre infrastructure.
How long does the course take?
About 3.8 hours of video lessons across eight teaching modules, plus the notes, practice questions, the final assessment and an optional project of around 10 hours. At a few hours a week it fits into three to four weeks.
What is the project?
You prepare a colocation data hall in Singapore for five 80 kW liquid-cooled AI racks: a cooling design basis, a BMS points list and alarm list, an integrated cooling acceptance test, and a capacity and efficiency report. A worked sample pack shows each document.
Do I need DCIM or BMS software?
No. The course explains what they do and how they are designed; the exercises use a spreadsheet.
Is the course really free?
Yes. Every module, the notes, the project and the final assessment. The only paid item is the certificate, if you want it.
What certificate do I get?
An EDWartens Certificate of Completion, issued when you pass the final assessment, with a number anyone can verify on our site. It is not a vendor or Uptime Institute certification, and EDWartens is not affiliated with either.

Want a live class and career support?

The Professional Module is five live days of Siemens PLC, HMI and SCADA with an instructor, then career sessions with our engineers and a CPD certificate.

Engineers talking beside an automation test rig, one looking up and smiling